Short-term changes in lens vault post implantable collamer lens surgery in myopic patients
Downloads
Published
DOI:
https://doi.org/10.58414/SCIENTIFICTEMPER.2025.16.7.09Keywords:
Implantable Collamer Lens, Intraocular Pressure, Spherical Equivalent, Anterior Chamber Depth, Best Corrective Visual AcuityDimensions Badge
Issue
Section
License
Copyright (c) 2025 The Scientific Temper

This work is licensed under a Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License.
Purpose: To evaluate short-term postoperative changes in lens vault and associated ocular parameters following Implantable Collamer Lens (ICL) implantation in myopic patients, and to identify preoperative predictors of vault behavior during the initial 15 days after surgery.Abstract
Subject and Methods: This cohort study included 202 eyes from 101 patients with myopia and astigmatism who underwent bilateral ICL implantation at Chaudhary Eye Centre & Laser Vision between October 2023 and December 2024. Preoperative and postoperative assessments included best-corrected visual acuity (BCVA), intraocular pressure (IOP), anterior chamber depth (ACD), and central vault measurements using the Anterion AS-OCT. Follow-ups were conducted on postoperative day 1 (POD 1) and day 15 (POD 15). Statistical analysis involved Wilcoxon tests, Fisher’s exact test, and mixed-model logistic regression to identify factors influencing vault changes.
Results: A significant reduction in lens vault was observed between POD 1 and 15 (mean difference = 50.5 μm; p < 0.001). ACD increased (mean = 0.0399 mm; p < 0.001), while IOP decreased (mean = 1.5 mmHg; p < 0.001). BCVA showed modest improvement (p = 0.041). Vault decreased in 75.2% of eyes, remained unchanged in 2%, and increased in 22.8%. Multivariate analysis revealed spherical equivalent (SE) as the only significant predictor of vault reduction (p < 0.001), with higher myopia associated with greater vault decrease.
Conclusion: Early postoperative changes in vault are significantly influenced by the degree of myopic correction. Higher preoperative myopia is associated with greater vault reduction, underscoring the importance of individualized preoperative planning and early postoperative monitoring to ensure optimal outcomes following ICL implantation.
How to Cite
Downloads
Similar Articles
- Yashodhara Y. Thaker, Divya Bhadauriya, Exploring communal strife: A comparative analysis of conflict in the novels of Khushwant Singh, Bhisham Sahni, Bapsi Sidhwa, and Amrita Pritam , The Scientific Temper: Vol. 15 No. spl-2 (2024): The Scientific Temper
- Princee Jain, Kalidasan Varathan, Effect of whole-body vibration on sensation, functional mobility and gait on diabetic neuropathy patients , The Scientific Temper: Vol. 16 No. 07 (2025): The Scientific Temper
- Vijai K. Visvanathan, Karthikeyan Palaniswamy, Thanarajan Kumaresan, Green ammonia: catalysis, combustion and utilization strategies , The Scientific Temper: Vol. 14 No. 01 (2023): The Scientific Temper
- V. Karthikeyan, C. Jayanthi, Advancements in image quality assessment: a comparative study of image processing and deep learning techniques , The Scientific Temper: Vol. 15 No. spl-1 (2024): The Scientific Temper
- Kalpana Deshmukh, Aparna Dighe, Harshal Raje, Impact of mindfulness-based programs on reducing stress and enhancing academic performance in college students , The Scientific Temper: Vol. 14 No. 04 (2023): The Scientific Temper
- Mithun Vinayaka Kulkarni, Vijayanand M, Syed Mudassir, Said Bakhit Ali Bakhit Tabook, Mohammed Hassan Abdullah Al-Hafeedh, An overview of wastepaper and carton recycling in Oman , The Scientific Temper: Vol. 16 No. Spl-2 (2025): The Scientific Temper
- Kumari Sammy, Sumita Singh, Coefficient of absorption cross-section of RN black holes , The Scientific Temper: Vol. 15 No. 04 (2024): The Scientific Temper
- Pankaj Kumar, Ambrish Pandey, Rajendrakumar Anayath, Study of print suitability of environment-friendly plastics using flexography printing , The Scientific Temper: Vol. 15 No. 01 (2024): The Scientific Temper
- Sharayu Mirasdar, Mangesh Bedekar, Knowledge graphs for NLP: A comprehensive analysis , The Scientific Temper: Vol. 16 No. Spl-1 (2025): The Scientific Temper
- Saroj Bala, Rajiv Ranjan Dwivedi, The Problematics of Parenthood in the Shiva Trilogy by Amish , The Scientific Temper: Vol. 13 No. 02 (2022): The Scientific Temper
You may also start an advanced similarity search for this article.

